Everything we can put in a specifier’s hands for a lighting-integrated stretch ceiling. Where a file exists, it downloads. Where it does not exist yet, it says so, because finding out at submittal is worse than finding out now.
Open downloads, no form.
Membrane Light Transmission ECS-TR-002
Total luminous flux transmittance, both faces. Translucent 42.0% diffused, transparent 70.5% diffused. Includes why the translucent film is the right choice over an LED array even though it passes less light. Poznan University of Technology, method per CIE 130-1998, report 0212/PRJG/0630.
Download PDF
ASTM E84 Surface Burning Characteristics ECS-TR-001
Intertek results reported per finish: gloss 5 / 300, matte 10 / 300, satin 15 / 250, flame spread and smoke developed. White specimens. The laboratory assigned no classification, and the report says so plainly, along with what the data does not cover.
Lighting profile drawings AP-301 / 302 / 305 / 306 / 307 / 212 / 213 / 216
Cove, linear Mini, Midi and Maxi, LuxForm and floating shapes. Cross sections and dimensions in DWG and PDF, in the profile library.
Open profiles
AP-213 LuxForm Revit family RFA
Geometry family for coordination and RCP layout, Revit 2024 format so it opens in 2024 through 2027. No photometric data is attached to this family.
Request
LED system configuration
24V constant voltage. 2700K, 3000K, 3500K, 4000K, 5000K, 6500K, tunable white and RGBW. Dimming and control on 0-10V, DALI-2 or DMX. Driver placement and access requirements. Configuration data, not photometric performance.
We would rather list these than let you assume they exist.
IES photometric files
In preparation. We hold no LM-79 data today, so we publish no lumen, lux, footcandle or efficacy figure for a finished assembly. Ask us what we can send now and we will tell you straight.
In preparation
LM-80 / TM-21 lumen maintenance
Not held by us. Available from the LED strip manufacturer on request for a specified product.
Not held
Acoustic absorption, ASTM C423 / NRC
Not held. We publish no NRC value. Testing of a specific build-up can be arranged for a project that needs a number.
Florida Product Approval / Miami-Dade NOA
Not held for membrane or track. If your permit path requires it, tell us early and we will say whether the project is a fit.
A lighting designer needs a light level. Until the IES files exist, this is how we close that gap, and on many projects it is the better answer anyway. On a large commercial project we build a mockup at the real cavity depth, with the actual membrane, the actual LED pitch and the actual driver, and you meter it in the room. A measured reading off the real assembly beats a modeled number from a generic file.
Send the RCP or a sketch. Within one business day we will tell you what data we can put behind it, and what we cannot.
Request lighting files or call +1 (754) 237-8474
Tell us what you are working on and what you need: IES files, lighting data or a layout review. We reply within one business day.
Share a few details and our team will follow up within one business day.